{"id":15434,"date":"2026-09-17T22:03:53","date_gmt":"2026-09-17T14:03:53","guid":{"rendered":"https:\/\/showinlighting.cn\/?p=15434"},"modified":"2026-09-17T22:03:54","modified_gmt":"2026-09-17T14:03:54","slug":"3-in-8-out-dmx512-merger-signal-combiner","status":"publish","type":"post","link":"https:\/\/showinlighting.cn\/ko\/3-in-8-out-dmx512-merger-signal-combiner\/","title":{"rendered":"8MG3BU 3\u2011In\u20118\u2011Out DMX512 Merger Signal Combiner With HTP LTP Backup Mode For Stage Live Production"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"15434\" class=\"elementor elementor-15434\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15e3984c e-flex e-con-boxed e-con e-parent\" data-id=\"15e3984c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4e40a2d2 elementor-widget elementor-widget-text-editor\" data-id=\"4e40a2d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<p class=\"wp-block-paragraph\">The <a href=\"https:\/\/showinlighting.cn\/ko\/product-category\/all-product\/stage-control-accessor\/artnet-converter\/\">3\u2011in\u20118\u2011out dmx512 merger signal combiner<\/a> is a rack\u2011mount professional DMX512 signal management hub built for complex live\u2011event lighting control systems. Reliable DMX signal transmission is critical for concerts, theatre performances and broadcast shows. System engineers often face real\u2011world troubles: multi\u2011console signal conflict, ground\u2011loop interference, long\u2011cable signal attenuation, and sudden main\u2011console crash during live performance. Simply paralleling multiple DMX sources will cause signal contention and may damage console transceiver chips. This unit solves above\u2011mentioned pain points with three selectable logic modes, full opto\u2011isolation protection and eight regenerated buffered outputs. It works as merger, priority switcher, backup fail\u2011over device and signal distributor all\u2011in\u2011one, lowering live\u2011show failure risk for rental houses and fixed\u2011venue installations. For extra stage control hardware reference, check <a href=\"https:\/\/showinlighting.cn\/ko\/\">our website<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/showinlighting.cn\/ko\/product\/3in-8out-dmx-merger-dmx512-1990-standard-htp-backup-mode-isolated-signal-inrush-protection-super-drive-led-indicator-wide-ac88-256v-global-rack-mount-three-input-eight-output-dmx-combiner-compact-19-i\/\"><img fetchpriority=\"high\" decoding=\"async\" width=\"960\" height=\"535\" src=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/1-3-960x535.png\" alt=\"3\u2011in\u20118\u2011out dmx512 merger signal combiner\" class=\"wp-image-15435\" srcset=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/1-3-960x535.png 960w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/1-3-800x446.png 800w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/1-3-150x84.png 150w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/1-3-768x428.png 768w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/1-3-18x10.png 18w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/1-3-600x334.png 600w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/1-3.png 976w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Core Function Overview Of 8mg3bu 3\u2011in\u20118\u2011out dmx512 merger signal combiner<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">DMX512 follows one\u2011master\u2011multiple\u2011slave serial protocol. When main console, backup console and effect console need to run simultaneously, you cannot directly parallel DMX outputs. This hardware receives up to three DMX input sources A\/B\/C, processes signal under user\u2011selected logic rules and outputs eight clean regenerated DMX universes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Three Selectable Operating Modes via Rear\u2011Panel DIP Switch<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>HTP (Highest Takes Precedence) Mode<\/strong> The unit compares channel value 0\u2011255 across three inputs and outputs the highest value.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Practical use case: Main show console plus secondary effect console. It avoids accidental black\u2011out caused by effect\u2011console zero\u2011value command. Widely adopted for architectural safety\u2011override lighting and multi\u2011source theatre control.<\/p>\n<\/blockquote>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>LTP (Latest Takes Precedence) Mode<\/strong> Priority is given to the most recently updated channel value regardless of brightness level.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Practical use case: TV studio multi\u2011operator workflow. Follow\u2011spot operator can instantly overwrite main console static parameters for real\u2011time performer tracking, fit for improvisational live broadcast production.<\/p>\n<\/blockquote>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>BACKUP Triple\u2011Redundant Fail\u2011Safe Mode<\/strong> Strict priority sequence: Input A = primary, Input B = first backup, Input C = second backup. When input A signal disappears (console crash, power loss or cable break), hardware switches to B within microseconds without visible fixture flicker. If B also fails, input C takes over.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Practical use case: Mission\u2011critical large\u2011scale concerts, festival main\u2011stage and broadcast events. Engineers get troubleshooting time while show keeps running for audience.<\/p>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/showinlighting.cn\/ko\/product-category\/all-product\/stage-control-accessor\/artnet-converter\/\"><img decoding=\"async\" width=\"960\" height=\"535\" src=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/2-2-960x535.png\" alt=\"rackmount dmx512 merger switcher\" class=\"wp-image-15436\" srcset=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/2-2-960x535.png 960w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/2-2-800x446.png 800w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/2-2-150x84.png 150w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/2-2-768x428.png 768w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/2-2-18x10.png 18w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/2-2-600x334.png 600w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/2-2.png 976w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/a><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Full Opto\u2011Isolation For Hardware Protection<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ground\u2011loop noise, stray voltage and surge from long DMX cables are common risks in complex venue power networks. Without isolation, surge can flow backward and burn expensive console transceiver chips. Every input and output port of this unit adopts complete opto\u2011isolation design. It builds non\u2011conductive physical barrier for each signal path. Short\u2011circuit or surge fault on output side will be contained locally and will not damage main or backup lighting consoles. This protects your whole DMX control ecosystem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Regenerated Super\u2011Drive 8\u2011Channel Buffered Outputs<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Standard DMX512 signal normally degrades beyond 100\u2011meter cable length, creating fixture mis\u2011addressing, random flicker or loss of control. Each of eight outputs is equipped with high\u2011current line\u2011driver circuit. It reshapes and restores DMX waveform amplitude. With high\u2011quality DMX cable, stable transmission distance can extend over 300 meters. These eight independent buffered outputs also work as built\u2011in DMX splitter. Users can distribute merged signal to multiple fixture zones without purchasing extra external distributor hardware, saving rack space and procurement cost.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/showinlighting.cn\/ko\/product-category\/all-product\/stage-control-accessor\/artnet-converter\/\"><img decoding=\"async\" width=\"960\" height=\"535\" src=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/3-2-960x535.png\" alt=\"tp ltp backup dmx combiner\" class=\"wp-image-15437\" srcset=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/3-2-960x535.png 960w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/3-2-800x446.png 800w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/3-2-150x84.png 150w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/3-2-768x428.png 768w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/3-2-18x10.png 18w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/3-2-600x334.png 600w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/3-2.png 976w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/a><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Front\u2011Panel Real\u2011Time LED Status Indication<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Technicians can diagnose signal status quickly during sound\u2011check or live\u2011show:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Yellow power LED: confirm unit power\u2011on status<\/li>\n\n\n\n<li>Input A\/B\u2011C green LED: light up when valid DMX signal is detected; turn off for signal loss<\/li>\n\n\n\n<li>Eight output LED: indicate active merged DMX output status Rapid visual feedback shortens fault\u2011finding time for touring crews.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Hardware &amp; Certification Highlights<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Universal wide\u2011voltage power supply: AC88\u2011256V, 50\/60Hz, adapts global venue power including generator\u2011powered festival sites. Internal T2A fuse provides surge protection.<\/li>\n\n\n\n<li>Standard 1U 19\u2011inch rack\u2011mount steel chassis (482\u00d7173\u00d746\u202fmm, net weight 1.75\u202fkg). Good electromagnetic shielding against nearby transformer and wireless\u2011device interference, suitable for rough touring transport inside flight case.<\/li>\n\n\n\n<li>Global safety certifications: CE, UL, GB 7000.15\u20112000. Qualified for international bidding projects, government venues and high\u2011end hotel installations.<\/li>\n\n\n\n<li>Package contents: DMX merger main unit, AC power cord, user operation manual.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Suitable Application Scenarios<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This 8mg3bu 3\u2011in\u20118\u2011out dmx512 merger signal combiner serves diversified B2B lighting\u2011control projects:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Concert Touring &amp; Music Festival Production<\/strong>: Activate BACKUP triple\u2011failover mode for main\u2011stage multi\u2011console redundant system, avoid show\u2011stopping failure in front of large\u2011size audience.<\/li>\n\n\n\n<li><strong>TV Studio &amp; Broadcast Facility<\/strong>: Apply LTP mode for multi\u2011operator collaborative lighting workflow between main lighting director and follow\u2011spot technicians, guarantee smooth on\u2011air transitions.<\/li>\n\n\n\n<li><strong>Theatre &amp; Performing\u2011Arts Center<\/strong>: Merge house console, follow\u2011spot console and special\u2011effect console; distribute signal to stage wash light and cyclorama fixtures via eight buffered outputs.<\/li>\n\n\n\n<li><strong>Theme\u2011Park &amp; Night\u2011Time Spectacle<\/strong>: Long\u2011distance DMX signal transmission for distributed outdoor fixture groups; opto\u2011isolation reduces interference risk from complex on\u2011site power grid.<\/li>\n\n\n\n<li><strong>Architectural &amp; Landscape Lighting<\/strong>: Use HTP logic for safety\u2011light priority override; multiple outputs cover building facade, bridge and monument lighting installation.<\/li>\n\n\n\n<li><strong>Stage\u2011Rental\u2011House Inventory<\/strong>: One\u2011rack\u2011unit hardware combines merger, priority switcher, backup fail\u2011over and DMX splitter functions. Reduce total flight\u2011case volume and enrich rental\u2011project solution capability.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Important operational note: Set DIP\u2011switch mode before show run; avoid switching logic mode during live performance to prevent unexpected lighting jump.<\/p>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/showinlighting.cn\/ko\/product-category\/all-product\/stage-control-accessor\/artnet-converter\/\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"535\" src=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/4-2-960x535.png\" alt=\"opto\u2011isolated dmx signal distributor\" class=\"wp-image-15438\" srcset=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/4-2-960x535.png 960w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/4-2-800x446.png 800w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/4-2-150x84.png 150w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/4-2-768x428.png 768w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/4-2-18x10.png 18w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/4-2-600x334.png 600w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/4-2.png 976w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">On\u2011Site Deployment &amp; Troubleshooting Advice<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Confirm DIP\u2011switch position matches your working requirement before power\u2011on. Do not toggle switch during live show playback.<\/li>\n\n\n\n<li>Check input\u2011port LED indicator status to verify whether main \/ backup console outputs valid DMX signal.<\/li>\n\n\n\n<li>For long cable deployment: Use high\u2011quality twisted\u2011pair DMX cable; take advantage of regenerated output to extend transmission range.<\/li>\n\n\n\n<li>In multi\u2011console BACKUP mode: Test fail\u2011over function in pre\u2011show rehearsal. Manually cut main\u2011console signal and verify glitch\u2011free switch\u2011over to backup source.<\/li>\n\n\n\n<li>Install unit inside standard 19\u2011inch equipment rack, keep ventilation space, avoid high\u2011temperature sealed cabinet environment.<\/li>\n\n\n\n<li>Keep original manual for overseas\u2011project technical reference and equipment hand\u2011over.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/showinlighting.cn\/ko\/product-category\/all-product\/stage-control-accessor\/artnet-converter\/\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"535\" src=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/5-2-960x535.png\" alt=\"stage lighting console backup unit\" class=\"wp-image-15439\" srcset=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/5-2-960x535.png 960w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/5-2-800x446.png 800w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/5-2-150x84.png 150w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/5-2-768x428.png 768w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/5-2-18x10.png 18w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/5-2-600x334.png 600w, https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/09\/5-2.png 976w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ for 8MG3BU 3\u2011In\u20118\u2011Out DMX512 Merger Signal Combiner<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q: What core value does 8mg3bu 3\u2011in\u20118\u2011out dmx512 merger signal combiner bring for lighting system engineers?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A: This all\u2011in\u2011one DMX processing hardware solves multi\u2011console signal conflict, ground\u2011loop surge risk, long\u2011distance signal attenuation and main\u2011console crash emergency backup. It integrates merger, priority switcher, triple fail\u2011over backup and 8\u2011port buffered splitter, improves whole\u2011system stability for touring and fixed\u2011installation lighting projects.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q: What is the difference among HTP, LTP and BACKUP mode?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A: HTP outputs highest channel\u2011value among inputs; LTP outputs latest\u2011changed channel\u2011value; BACKUP works under strict A\u2011B\u2011C priority hierarchy and auto\u2011switches upon signal loss. Each mode targets distinct live\u2011show workflow requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q: Can this unit work as a simple DMX splitter without merging multi\u2011console signals?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A: Yes. Feed single DMX source into Input A, select proper mode. Eight regenerated opto\u2011isolated outputs work as high\u2011performance 1\u2011to\u20118 DMX distributor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q: How long DMX cable can I use with this merger\u2019s regenerated output?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A: Using professional\u2011grade DMX twisted\u2011pair cable, stable transmission can reach over 300\u202fmeters, far beyond standard 100\u2011meter DMX limit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q: Will switching DIP\u2011switch mode during live\u2011show cause lighting glitch?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A: Yes. Mode change will rebuild signal logic. Always configure DIP\u2011switch setting during pre\u2011show setup or rehearsal, not during live performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q: Does opto\u2011isolation function protect lighting consoles against surge damage?<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A: Opto\u2011isolation creates non\u2011conductive barrier for each signal port. Short\u2011circuit or surge fault on output side will not feed back and burn console internal transceiver chips, greatly lowering expensive hardware\u2011repair risk.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/showinlighting.cn\/ko\/product-category\/all-product\/stage-control-accessor\/artnet-converter\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"202\" src=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/06\/1380-3.webp\" alt=\"dmx signal regenerator for touring show\" class=\"wp-image-7786\"\/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">B2B Wholesale &amp; Project\u2011Solution CTA<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If you are stage\u2011rental operator, lighting\u2011system integrator or venue technical contractor searching for reliable <strong>8mg3bu 3\u2011in\u20118\u2011out dmx512 merger signal combiner<\/strong>, we provide function\u2011selection guidance, wiring\u2011scheme suggestion and bulk\u2011order\u2011wholesale quotation for touring\u2011concert, theatre, broadcast\u2011studio and architectural\u2011lighting projects. Contact our B2B sales\u2011engineering\u2011team today to receive full datasheet, user manual and overseas\u2011project\u2011support information for your upcoming lighting\u2011control\u2011system build.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>#showinlighting #dmx512merger #stagelightcontrol #htpltpdmx #dmxfailover #rackmountdmx #touringstagegear #theatrelightingtech #broadcastlighting #stagerentalgear #b2bstageequipment<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/showinlighting.cn\/ko\/product-category\/all-product\/stage-control-accessor\/artnet-converter\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"219\" src=\"https:\/\/showinlighting.cn\/wp-content\/uploads\/2026\/06\/1380-1.webp\" alt=\"live\u2011event dmx processing hardware\" class=\"wp-image-7784\"\/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>The 3\u2011in\u20118\u2011out dmx512 merger signal combiner is a rack\u2011mount professional DMX512 signal management hub built for complex live\u2011event lighting control systems. Reliable DMX signal transmission is critical for concerts, theatre performances and broadcast shows. System engineers often face real\u2011world troubles: multi\u2011console signal conflict, ground\u2011loop interference, long\u2011cable signal attenuation, and sudden main\u2011console crash during live performance. [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":15435,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[2554,2556,2552,2557,2553,2555,2551],"class_list":["post-15434","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-3-in-8-out-dmx512-merger-signal-combiner","tag-dmx-signal-regenerator-for-touring-show","tag-htp-ltp-backup-dmx-combiner","tag-live-event-dmx-processing-hardware","tag-opto-isolated-dmx-signal-distributor","tag-rackmount-dmx512-merger-switcher","tag-stage-lighting-console-backup-unit"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"_links":{"self":[{"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/posts\/15434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/comments?post=15434"}],"version-history":[{"count":6,"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/posts\/15434\/revisions"}],"predecessor-version":[{"id":15445,"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/posts\/15434\/revisions\/15445"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/media\/15435"}],"wp:attachment":[{"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/media?parent=15434"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/categories?post=15434"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/showinlighting.cn\/ko\/wp-json\/wp\/v2\/tags?post=15434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}